18L Dental Autoclave Steam Sterilizer Medical sterilizition Pressure Gauge Safe

$ 369.6

Availability: 100 in stock
  • STERILIZATION TIME: 25Min / 6Min
  • Warranty: 2 year
  • Sterilizer Type: Autoclave (Steam Sterilizer)
  • Brand: Denshine
  • All returns accepted: Returns Accepted
  • TEMP CONTROL DESIGN: chip control
  • UPC: Does Not Apply
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Restocking Fee: No
  • TEMP/PRESSURE: 121℃/0.12Mpa ; 134℃/0.22Mpa
  • Item must be returned within: 30 Days
  • Condition: New
  • MPN: Does Not Apply
  • SAFETY: Heating-over protection ; safety valve
  • Power: AC110V/900W/8A ; AC220V/900W/4A
  • Bundle Listing: Yes
  • Machine size: (L)58×(W)39×(H)36 C
  • chamber size: stainless steel #304 ; 18Liter ; (Ø)25×(D)35 CM
  • Colour: as picture shows
  • Country/Region of Manufacture: China
  • EAN: Does Not Apply
  • Model: 370131-110V 370132-220V
  • 510K NO.: K122774
  • Return shipping will be paid by: Buyer

    Description

    FDA Statement:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
    All of our products are CE approved.
    Our 510(k) Number is K122774.
    Description:
    370131 110v
    370132 220v
    Specification:
    CHAMBER SIZE : stainless steel #304 ; 18Liter ; (Ø)25
    ×
    (D)35 CM
    MACHINE SIZE : (L)58
    ×
    (W)39
    ×
    (H)36 C
    POWER : AC110V/900W/8A ; AC220V/900W/4A
    TEMP/PRESSURE : 121

    /0.12Mpa ; 134

    /0.22Mpa
    STERILIZATION TIME : 25Min / 6Min
    SAFETY : Heating-over protection ; safety valve
    TEMP CONTROL DESIGN : chip control
    Safety equipment:
    1.Pressure adjustment: adjust the inter pressure, if over standard value automatic vent
    2.Avoild overheat protect device: when inter temperature overheat, power break electric current automatically.
    OPTIONAL ACCESSORIES :
    tray basket
    ×
    1pc ;  tray holder
    1pc
    Sterilization tray
    ×
    3pcs ;  steam exhaust pipe
    1pc
    CAUTION:
    1.After the completion of disinfection

    Please to wait for 10 minutes.
    Before open the DOOR(Do not close the power switch and close the steam
    emissions switch).
    2.Before each use.Must supply water 800ml

    (Distilled water is the bast).
    3.Please close steam emissions switch.Before In the disinfection.
    4.Do not use any corrosive or chemical water as the disinfection.
    5.Do not share the same electricoutllet with other electrical apparetus.
    6.Please pay attention to correct voltage and frequency.
    7.Connect steam exhaust pipe with the steam vent

    Before operation.
    Package Includes:
    1*main unit with accessories
    Payment
    We accept PayPal only. We will ship out the item after receiving cleared payment.
    Shipping
    A complete and correct shipping address is essential.
    Customers with shipping addresses outside of the U.S. are responsible for all duties and import taxes. Please contact your customs for information
    Return Policy
    All items are in brand new condition unless specified.
    FDA declaration:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (Seller Name: Christine Geng;Country: China;City: Beijing;TEL.:86-15210656055).
    This item has been cleaned and treated according to the manufacturer's instructions.
    The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
    The Powered Surgical Instrument / Hair Remove Device
    is certified with the US FDA 510(k) Number:K180353
    The Powered Surgical Instrument / Hair Remove System
    is certified with the US FDA 510(k) Number:K141973
    massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA
    510(k) Number:K161892
    Contact Us
    Any questions, please contact us through eBay message or e-mail, We will reply within 1-2 business days (public holidays not included).
    working time: Monday - Friday   9:00 AM - 5:30PM (Beijing)